Skip to main content

Exterior-only specialists

Built for body corporates, HOAs, and West Rand estates — not industrial warehouses

We deliberately exclude interior work, high-rise corporate blocks, and massive industrial sites. That focus is your advantage: zero interior disruption and estate-scale programmes we can actually phase.

Exterior only

Roofs, facades, and boundary walls — zero interior access, zero resident key handovers.

Agile small teams

One micro-zone at a time. We finish a block before advancing — not fifty workers across the estate.

Phased chunking

36–48 month programmes aligned to reserve fund accruals — not a single capital spike.

Material science precision

Doser hygrometer diagnostics below 8% moisture, 100 µm Micatex DFT, and polymer-modified tanking before topcoat.

Complex roofs

Thermal protection, ridge sealing, IBR and tiled systems.

Boundary walls

Rising and lateral damp, efflorescence, perimeter security aesthetics.

Estate facades

UV elastomerics, crack bridging, HOA colour compliance.

Parapet waterproofing

Box gutters, flashings, moisture ingress before topcoat.

How we operate

Framework of readiness — proof without a legacy portfolio

Trustees cannot approve multi-million Rand reserve fund spend on vague promises. This is the exact technical sequence our agile teams execute on every exterior phase — logged, measured, and handed over for your PMR 22 file.

Moisture diagnostics

SANS 10400 substrate verification before any primer.

  • Masonry moisture must read below 8% on BD 2 scale (Doser hygrometer).
  • Structural timber below 17% where brandering is coated.
  • Readings logged in the on-site QA record before coatings commence.

Damp & tanking remediation

Lateral damp stripped to brick, tanked, and DPC-injected where required.

  • Effloresced plaster removed on terraced boundary walls.
  • PRO-STRUCT 506 / Eucoseal class cementitious slurry applied.
  • Silane or silicone DPC cream injected at mortar line.

Measured coating application

Plascon Micatex applied to documented WFT/DFT targets.

  • 30–50 µm DFT per coat; ~100 µm aggregate system target.
  • Electronic gauge readings recorded during application.
  • Crack-bridging elastomeric film for Highveld thermal shock.

Phased handover

Photographic QA log and walk-through before demobilisation.

  • Snags closed in the active micro-zone before moving on.
  • PMR 22 reserve drawdown schedule updated for the completed phase.
  • Site left tidy — personnel never enter sectional title interiors.

Independent QA & material log

Empirical metrics — not “quality workmanship” platitudes

Every exterior phase is documented against SANS moisture thresholds, tanking protocols, and measured dry film thickness. Your managing agent gets numbers they can defend at the AGM.

Substrate preparation

< 8% moisture · SANS 10400
Typical competitor claim
We wash the walls before painting.
Krugersdorp Painters QA metric

Doser hygrometer readings confirming masonry moisture strictly below 8% (BD 2 scale) per SANS 10400 before primer.

Structural waterproofing

PRO-STRUCT 506 · DPC injection
Typical competitor claim
We fix peeling paint and rising damp.
Krugersdorp Painters QA metric

Documented PRO-STRUCT 506 cementitious tanking and chemical DPC injection (Dryzone/Microsilan class) on lateral damp zones.

Coating application

100 µm DFT · Plascon Micatex
Typical competitor claim
Two coats of premium paint.
Krugersdorp Painters QA metric

Non-destructive gauge readings targeting 100 µm aggregate DFT on Plascon Micatex — bridging hairline cracks to 0.08 mm.

Our specialized teams utilize calibrated moisture diagnostics and structural analysis to deliver your tailored, phased maintenance proposal.